Simple L200 Charger
This circuit came about as the result of an urgent need for a NiMH battery charger. No suitable dedicated IC being immediately to hand, the author pressed an L200 regulator and a 4.7 kΩ NTC thermistor into service. Those components were enough to form the basis of a charger with a cut-of f condition based on cell temperature rise rather than relying on the more common negative delta-V detection.

The circuit uses the L200 with the thermistor in the feedback loop. When ‘cold’ the output volt age of the regulator is about 1.55 V per cell; when ‘warm’, at a cell temperature of about 35 °C to 40 °C, the out-put voltage is about 1.45 V per cell and the thermistor has a resistance of about 3.3 kΩ. This temperature sensing is enough to pre-vent the cells from being overcharged. P1 adjusts the charging voltage, and R2 limits the charge current to 320 mA. The IC is fitted with a small 20 K/W heatsink as it dissipates around 1.2 watts in use.

The charger circuit can be connected permanently to the battery pa ck . Charging starts when a ‘ wall wart ’ adaptor is connected to the input of the charger. The unregulated 12 V supply used by the author delivered an open- circuit voltage of 18 V, dropping to 14 V under load. Even though the charge voltage is reduced when charging is complete, the cells should not be left permanently on charge.

The author uses the circuit to charge the battery in a torch. After three years and some 150 charge cycles the cells are showing no signs of losing any capacity.

Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Using the SG3525 PWM Controller Explanation and Example Circuit Diagram Schematic of Push Pull Converter

PWM is used in all sorts of power control and converter circuits. Some common examples include motor control, DC-DC converters, DC-AC inverters and lamp dimmers. There are numerous PWM controllers available that make the use and application of PWM quite easy. One of the most popular of such controllers is the versatile and ubiquitous SG3525 produced by multiple manufacturers – ST Microelectronics, Fairchild Semiconductors, On Semiconductors, to name a few. SG3525 is used extensively in DC-DC converters, DC-AC inverters, home UPS systems, solar inverters, power supplies, battery chargers and numerous other applications. With proper understanding, you can soon start using SG3525 yourself in such applications or any other application really that demands PWM control. Before going on to the description and application, let’s first take a look at the block diagram and the pin layout. Pins 1 (Inverting Input) and 2 (Non Inverting Input) are the inputs to the on-board error amplifier. If you a...

Automatic Intruder Alarm Circuit Diagram

Description: This is a simple single-zone burglar alarm circuit. Its features include automatic Exit and Entry delays and a timed Bell/Siren Cut-Off. It's designed to be used with the usual types of normally-closed input devices such as - magnetic reed contacts - micro switches - foil tape - and PIRs. But it can be Easily Modified to accept normally-open triggering devices - such as pressure mats. Circuit Diagram   Notes:   It's easy to use. First check that the building is secure and that the green LED is lit. Then move SW1 to the "set" position. The red LED will light. You now have about 30 seconds to leave the building. When you return and open the door - the Buzzer will sound. You then have about 30 seconds to move SW1 to the "off" position. If you fail to do so - the relay will energize and the Siren will sound. While at least one of the switches in the normally-closed loop remains open - the Siren will continue to sound. However, about 15-minutes aft...