Skip to main content

Posts

Showing posts with the label HMI

Communication between Delta HMI and PC

Before performing any communication, it is better to understand the hardware interface of Delta Hmi TP04 series and how to set the communication settings in TPEditor software program. Please refer to the following sections for the method of communication. An external 24V DC power is required when activating TP04 series. After the power is in connected to TP04 series, the start-up display will show up first and then the system main menu of TP04 series will appear. Choose “4.TP SETUP” > “1.Communication Protocol”. There are three items regarding the communication settings: TP Settings: It is used to set the communication address of TP series. RS232: It is used to set the transmission speed (baud rate), data length, parity check, and stop bit of     RS-232 communication. RS485: It is used to set the transmission speed (baud rate), data length, parity check, and stop bit of RS-485 communication. The above three items should be set in accordance with the settings set in T...

Communication Between two E1000 HMI and mitsubishi Fx2n PLC

Connection between 2 E-Terminals and FX2N PLC.  The required material for the setup is as follows Sr. no. Material 1 PLC            :FX Series 2 CPU             :FX2N 3 HMI           : E1101 ,E1071 4 HMI S/W     :E-Designer Ver: 7.31   Two E-Terminals are connected to FX-2N PLC using MISTU- CAB14A          and MISTU-CAB 6Aa    The required cables are as follows      Sr. no. Item Description 1 MISTU-CAB 6Aa Prog.Cable For E-Terminal And Comm. Cable between E1071 and E-1101 2 MISTU-CAB 14A Comm. Cable for E-Terminal to FX2N PLC   E1101 Program Setting STEP 1: Select Controller FX and FX Series Serial driver for Controller.  Snapshot of Controller 1 Setting in E1101  Put Controlle...