Allen Bradley PLC PWM Pulse Width Modulation error codes





 Allen Bradley PLC PWM (Pulse Width Modulation) error codes



 
Following Table Shows PWM instruction Error Codes with Description.








Error Code
Error Name
Description
-2

OverlapError
An output overlap is detected.  Multiple functions are assigned to the same physical output.  This is a configuration error.  The controller faults and the User Fault Routine does not execute.
-1
Output Error
An invalid output has been specified.  Output 2 and output 3 are the only valid choices.  this is a configuration error.  The controller faults and the User Fault Routine does not execute.
0
Normal
0=No error
1

HardstopError
This error is detected whenever a hardstop is detected.  This error does not fault the controller.  It is automatically cleared when the hardstop condition is removed.
2
OutputForced Error
The configured PWM output (2 or 3) is currently forced.  The forced condition must be removed for the PWM to operate.  This error does not fault the controller.  It is automatically cleared when the force condition is removed.
3
FrequencyError
The frequency value is less than 0 or greater than 20,000.  This error faults the controller.  It can be cleared by logic within the User Fault Routine.

4
Accel/DecelError
Upon a transition to the Normal state, the Accel/Decel is tested.  If Accel/Decel is less than zero or greater than 50*Frequency when frequency ramping is selected (PP=1), an Accel/Decel Error is reported.  (MicroLogix 1200 Series A and all 1500 Series B.)
5
Duty CycleError
The PWM duty cycle is either less than zero or greater than 1000.  This error faults the controller.  It can be cleared by logic within the User Fault Routine

                            Sourse :Rockwell Inc.







Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Using the SG3525 PWM Controller Explanation and Example Circuit Diagram Schematic of Push Pull Converter

PWM is used in all sorts of power control and converter circuits. Some common examples include motor control, DC-DC converters, DC-AC inverters and lamp dimmers. There are numerous PWM controllers available that make the use and application of PWM quite easy. One of the most popular of such controllers is the versatile and ubiquitous SG3525 produced by multiple manufacturers – ST Microelectronics, Fairchild Semiconductors, On Semiconductors, to name a few. SG3525 is used extensively in DC-DC converters, DC-AC inverters, home UPS systems, solar inverters, power supplies, battery chargers and numerous other applications. With proper understanding, you can soon start using SG3525 yourself in such applications or any other application really that demands PWM control. Before going on to the description and application, let’s first take a look at the block diagram and the pin layout. Pins 1 (Inverting Input) and 2 (Non Inverting Input) are the inputs to the on-board error amplifier. If you a...

Automatic Intruder Alarm Circuit Diagram

Description: This is a simple single-zone burglar alarm circuit. Its features include automatic Exit and Entry delays and a timed Bell/Siren Cut-Off. It's designed to be used with the usual types of normally-closed input devices such as - magnetic reed contacts - micro switches - foil tape - and PIRs. But it can be Easily Modified to accept normally-open triggering devices - such as pressure mats. Circuit Diagram   Notes:   It's easy to use. First check that the building is secure and that the green LED is lit. Then move SW1 to the "set" position. The red LED will light. You now have about 30 seconds to leave the building. When you return and open the door - the Buzzer will sound. You then have about 30 seconds to move SW1 to the "off" position. If you fail to do so - the relay will energize and the Siren will sound. While at least one of the switches in the normally-closed loop remains open - the Siren will continue to sound. However, about 15-minutes aft...