The circuit shown in Fig. 1 provides a mechanical means of striking two gongs or chimes in sequence -- one when the doorbell is pressed, the other when it is released. This it does by briefly activating two solenoids in succession -- or even two motors to which suitable hammers are attached. It is a circuit which was rejected by a publisher, for the reason that it was thought to be too complex -- which really it is. I had been designing various embodiments of the same idea, and this embodiment was not the most elegant. Having said this, it works perfectly well.

The circuit is unusual from the point of view that it is based on two pulse shorteners, IC1a and IC1b. These are essentially two monostable timers with special arrangements at their inputs. Of critical importance, in these circuits, is that the potential between S1 and R1 should change fairly rapidly when S1 is pressed, and that the trigger inputs of IC1a and IC1b should be suitably biased.

Universal Ding-Dong Circuit Diagram


Circuit Project: Universal Ding-Dong

C2 serves to debounce pushbutton switch S1 – however, its value cannot be too high, due to the requirements of the pulse shortener circuit. TR1 and R2 serve as an inverter. IC1a is effectively a negative-edge-triggered monostable timer, so that when pushbutton switch S1 is pressed, IC1a's output goes “high”, TR2 conducts, and solenoid SOL1 is activated. D1 suppresses back-EMF, which could potentially destroy the IC.

When pushbutton S1 is released, C2 rapidly discharges through R1. IC1b is effectively a positive-edge-triggered monostable timer, so that when IC1b's output goes "high", TR3 conducts, activating solenoid SOL2. D2 is again provided to suppress back-EMF. R9 and R10 are not strictly necessary in the circuit, but limit damage in the unlikely event of the failure of TR2 or TR3.

Unless a large battery is used for B1, C1 is needed to provide the "whack" required for solenoids SOL1 and SOL2. If the pulses which activate SOL1 and SOL2 seem to be too long or too short (they are less than a tenth of a second each as shown), the values of R7 and C5, respectively R8 and C6, may be adjusted according to the formula t = 1.1 R C seconds. TR1 is a miniature MOSFET. If an equivalent is required, it may be replaced with the same MOSFET as is used for TR2 and TR3. If TR2 and TR3 are not to be found, rough equivalents may be used, on condition that their gate voltage is at least a quarter below the supply voltage.

Ideally, solenoids SOL1 and SOL2 would be 12V push-action types, or pull-action types which have a thrust pin at the back. However, plain pull-action types should work if they are touching the chimes or gongs when the circuit is at rest (they would then pull back, bounce, and strike). Small DC motors may be used with hammers attached, with suitable series resistors if required. These would likely need longer timing periods for monostable timers IC1a and IC1b.

The circuit may use the (original) bipolar version of the 555 timer IC, or its more recent CMOS equivalents. If a CMOS equivalent is used, standby current is likely to be below 2mA. That is, an AA alkaline battery pack would last about two months on standby. For longer periods, a regulated power supply is recommended. The supply voltage will ideally be 12V, but may be reduced to 9V.



Copyright Rev. Thomas Scarborough
[Contact the author of this article at scarboro@iafrica.com]

Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Using the SG3525 PWM Controller Explanation and Example Circuit Diagram Schematic of Push Pull Converter

PWM is used in all sorts of power control and converter circuits. Some common examples include motor control, DC-DC converters, DC-AC inverters and lamp dimmers. There are numerous PWM controllers available that make the use and application of PWM quite easy. One of the most popular of such controllers is the versatile and ubiquitous SG3525 produced by multiple manufacturers – ST Microelectronics, Fairchild Semiconductors, On Semiconductors, to name a few. SG3525 is used extensively in DC-DC converters, DC-AC inverters, home UPS systems, solar inverters, power supplies, battery chargers and numerous other applications. With proper understanding, you can soon start using SG3525 yourself in such applications or any other application really that demands PWM control. Before going on to the description and application, let’s first take a look at the block diagram and the pin layout. Pins 1 (Inverting Input) and 2 (Non Inverting Input) are the inputs to the on-board error amplifier. If you a...

Automatic Intruder Alarm Circuit Diagram

Description: This is a simple single-zone burglar alarm circuit. Its features include automatic Exit and Entry delays and a timed Bell/Siren Cut-Off. It's designed to be used with the usual types of normally-closed input devices such as - magnetic reed contacts - micro switches - foil tape - and PIRs. But it can be Easily Modified to accept normally-open triggering devices - such as pressure mats. Circuit Diagram   Notes:   It's easy to use. First check that the building is secure and that the green LED is lit. Then move SW1 to the "set" position. The red LED will light. You now have about 30 seconds to leave the building. When you return and open the door - the Buzzer will sound. You then have about 30 seconds to move SW1 to the "off" position. If you fail to do so - the relay will energize and the Siren will sound. While at least one of the switches in the normally-closed loop remains open - the Siren will continue to sound. However, about 15-minutes aft...