Skip to main content

8 Digit Code Lock for Appliance Switching Circuit Diagram


This code lock is useful for appliances requiring exclusive or authorised use by those who know the preset code. If desired, the code can be changed.

The circuit doesn’t require additional AND or NOT gate operations at the outputs. It uses two pairs of 4-way DIP switches. The code is set using DIP switches DIP3 and DIP4. Then these two switches are hidden inside the assembly. With DIP3 and DIP4, up to 256 code combinations are possible. The unlocking code is set by the user using DIP switches DIP1 and DIP2, which is compared with the preset code entered earlier via DIP3 and DIP4. If the two codes match, transistor T1 conducts.

8-Digit Code Lock for Appliance Switching Circuit Diagram

8-Digit Code Lock for Appliance Switching Circuit Diagram
 

The codes are compared using two cascaded 4-bit magnitude comparator Ics (IC1 and IC2). If the input nibble present at DIP1 matches with preset DIP3 nibble, output pin 6 of IC1 (connected to input pin 3 of IC2) goes high. Now if nibble present at DIP2 matches with the preset nibble at DIP4, pin 6 of IC2 also goes high. This high output drives transistor T1 and the appliance turns on via relay contacts.

After use, disturb the positions of DIP1 and DIP2 so that the appliance can’t be operated by unauthorised persons. This will also switch the appliance off.

The circuit works off a 5V DC power supply. Hidden switch S0 can be used  to manually turn on/off the appliance if you have forgotten the preset code.

Caution. You may use this code lock at your own risk. After all, a clever intruder will try all 256 possible combinations one after the other to break the secret code.


Author :  Maneesh Chadha Sorced By : EFY

Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Using the SG3525 PWM Controller Explanation and Example Circuit Diagram Schematic of Push Pull Converter

PWM is used in all sorts of power control and converter circuits. Some common examples include motor control, DC-DC converters, DC-AC inverters and lamp dimmers. There are numerous PWM controllers available that make the use and application of PWM quite easy. One of the most popular of such controllers is the versatile and ubiquitous SG3525 produced by multiple manufacturers – ST Microelectronics, Fairchild Semiconductors, On Semiconductors, to name a few. SG3525 is used extensively in DC-DC converters, DC-AC inverters, home UPS systems, solar inverters, power supplies, battery chargers and numerous other applications. With proper understanding, you can soon start using SG3525 yourself in such applications or any other application really that demands PWM control. Before going on to the description and application, let’s first take a look at the block diagram and the pin layout. Pins 1 (Inverting Input) and 2 (Non Inverting Input) are the inputs to the on-board error amplifier. If you a...

Automatic Intruder Alarm Circuit Diagram

Description: This is a simple single-zone burglar alarm circuit. Its features include automatic Exit and Entry delays and a timed Bell/Siren Cut-Off. It's designed to be used with the usual types of normally-closed input devices such as - magnetic reed contacts - micro switches - foil tape - and PIRs. But it can be Easily Modified to accept normally-open triggering devices - such as pressure mats. Circuit Diagram   Notes:   It's easy to use. First check that the building is secure and that the green LED is lit. Then move SW1 to the "set" position. The red LED will light. You now have about 30 seconds to leave the building. When you return and open the door - the Buzzer will sound. You then have about 30 seconds to move SW1 to the "off" position. If you fail to do so - the relay will energize and the Siren will sound. While at least one of the switches in the normally-closed loop remains open - the Siren will continue to sound. However, about 15-minutes aft...