Description 
The circuit protection output of power amplifiers and loudspeakers, dispose certain interesting elements, as the isolation of loudspeakers from the exit of amplifier, when is presented continuous voltage in his exit or when the temperature of heatsink, goes up excessively, providing simultaneously and time delay in the connection loudspeakers in the amplifier, so that we avoid pass in them, the known annoying noises from the charge - discharge of capacitors of supply. It’s constituted by a binary comparator [ IC1 ], the transistors Q1-2 and indicative LED D5-6. The supply of circuit can become from positive voltage [ Point A ] of mainly power supply, which is stabilised by the D3 and the R17, in + 15V. Point B is connected in one of the secondary AC coil of main transformer. If close the main switch of main line AC, then a AC voltage (in secondary coil of transformer), is presented in the point B, it’s rectified from the D2 and it supply with negative voltage, via the R9, the Q3, this cut off and it begin charge the C4 via the R10-11. As long as time therefore last the charge of capacitor, the input [+] of comparator IC2B is found in low level concerning input [-]. The exit of IC2B, has low level, therefore the Q4 remain in cutt off and the RL1 remain deactivate, the D6 he is ON. Just the C4 charged, change the situation of IC1B, is activated the RL1, the loudspeaker are connected in the amplifier output, the D6 it OFF. When it’s interrupted the supply, all the process is inverted, and the loudspeaker disconnect, without pass annoying noises. If as long as it work the circuit, is presented problem of continuous voltages in the exit of amplifier then turn off of RL1 and protected the loudspeakers. This become with help the Q1-2. The acoustic signal from the exit of power amplifier, is led to point D, the alternate voltages is led to the ground via the C1-2, that create a not polar capacitor. Continuous voltages, bigger than + 1.7V or smaller than –4.8V, activate immediately the Q1 or the Q2, respectively. With the activation of transistors goes down the level of input [+] of IC1B, so that turn off and the RL1. A other section of protection that for us provide the circuit is the thermic protection. This become with the help of sensor temperature the RTH, which is a resistor of type PTC (positive factor of temperature), and is found placed above in heatsink, where are found also the power transistors. Her price increase, with the increase of temperature, until the potential in input [-] of IC1A, goes up above from the level of input [+], which is determined with the voltage divider R2-3. As soon as the level in input [-] exceed the level of input [+], the exit of IC1A, it return in low level, compelling and the IC2B to change situation, turn off the RL1 and to turn on the D5, that show the thermic protection. In the circuit the limit above which it exist clue of thermic protection they are 70?C. If it’s presented instability, in this stage, in operation of RL1, should be changed the R4, with other of smaller price. The circuit was published in magazine “Elektor” 12/95. 
Circuit Diagram
Part List
  • R1-2=27 Kohms
  • R3=1.4 Kohms
  • R4=1 Mohms
  • R5-14-17=3.3 Kohms
  • R6-7=100 Kohms
  • R8=47 Kohms
  • R9-11=120 Kohms
  • R10=470 Kohms
  • R12=15 Kohms
  • R13=1.5 Kohms
  • R15=4.7 Kohms
  • R16=33 Kohms
  • R18=1.5 Kohms 5W
  • RTH=KTY81-122
  • C1-2=100uF 63V
  • C3=470nF 100V MKT
  • C4-5=47uF 25V
  • IC1=LM393
  • Q1-2-3=BC337
  • Q4=BC639
  • D1=1N4148
  • D2=1N4004
  • D3=15V 1.5W Zener
  • D4=1N4002
  • D5-6=LED
  • RL1=24V Relay 
Source -http://users.otenet.gr/~athsam/protection_2_EN.htm

Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Using the SG3525 PWM Controller Explanation and Example Circuit Diagram Schematic of Push Pull Converter

PWM is used in all sorts of power control and converter circuits. Some common examples include motor control, DC-DC converters, DC-AC inverters and lamp dimmers. There are numerous PWM controllers available that make the use and application of PWM quite easy. One of the most popular of such controllers is the versatile and ubiquitous SG3525 produced by multiple manufacturers – ST Microelectronics, Fairchild Semiconductors, On Semiconductors, to name a few. SG3525 is used extensively in DC-DC converters, DC-AC inverters, home UPS systems, solar inverters, power supplies, battery chargers and numerous other applications. With proper understanding, you can soon start using SG3525 yourself in such applications or any other application really that demands PWM control. Before going on to the description and application, let’s first take a look at the block diagram and the pin layout. Pins 1 (Inverting Input) and 2 (Non Inverting Input) are the inputs to the on-board error amplifier. If you a...

Automatic Intruder Alarm Circuit Diagram

Description: This is a simple single-zone burglar alarm circuit. Its features include automatic Exit and Entry delays and a timed Bell/Siren Cut-Off. It's designed to be used with the usual types of normally-closed input devices such as - magnetic reed contacts - micro switches - foil tape - and PIRs. But it can be Easily Modified to accept normally-open triggering devices - such as pressure mats. Circuit Diagram   Notes:   It's easy to use. First check that the building is secure and that the green LED is lit. Then move SW1 to the "set" position. The red LED will light. You now have about 30 seconds to leave the building. When you return and open the door - the Buzzer will sound. You then have about 30 seconds to move SW1 to the "off" position. If you fail to do so - the relay will energize and the Siren will sound. While at least one of the switches in the normally-closed loop remains open - the Siren will continue to sound. However, about 15-minutes aft...