Geiger Counter Uses Cockroft Walton Multiplier



The recent tsunami in Japan and the on-going calamity with the Fukushima nuclear power plant has apparently greatly increased sales of radiation meters, not only in Japan but elsewhere around the world. This device will allow an estimation of the level of radioactivity, being sensitive enough for background radiation monitoring or to provide an estimation of the level of radioactivity from sample objects such as Thorium gas mantles in LPG lamps. The circuit is compatible with several Geiger Muller tubes and three types of indication are provided: the good old-fashioned audible click with each discharge, a flashing LED or an analog meter providing a rough average of radiation levels.

Geiger Counter Uses Cockroft-Walton Multiplier Circuit

Geiger Counter Uses Cockroft-Walton Multiplier

A normal background count in New Zealand with the smaller GM LND712 tube is around 30 counts per minute, while the larger and more-sensitive LND7312 pancake tube will count about four times this figure. Both GM tubes will detect alpha, beta and gamma radiation. Unless the tube is “filtered”, there is no way of knowing just what type of radiation is being detected, although a rough guess can be made. Alpha particles will be stopped by placing a sheet of paper between the tube and the source, Beta particles (electrons) will be stopped with a few layers of aluminium foil and the more lively Gamma rays will need a layer of lead.

The circuit provides a regulated 500V supply for the Geiger Muller tube. This voltage places the tube into its linear operating mode so that a discharge inside the tube will occur when a particle enters through the mica window of the tube and causes the gas to ionise. The very short pulse produced is stretched and used to signal that a discharge has occurred. The power supply consists of an oscillator and small transistor driving the 6V secondary of a 240VAC mains transformer. The stepped up output of the transformer is fed to a Cockroft-Walton voltage multiplier consisting of diodes D3-D7 and the associated 47nF 630V metallised polyester capacitors.

IC1 is a 40106 Schmitt trigger inverter and IC1a is connected as an oscillator running at several hundred hertz. This is buffered by IC1b and fed to the base of NPN transistor Q1 which then drives the abovementioned transformer. IC1c acts as an error amplifier to regulate the high voltage fed to the GM tube. A portion of the DC voltage produced at the junction of diodes D4 & D5 is monitored by a voltage divider consisting of the 4.7MO and 47kO resistors, in combination with trimpot VR1. When the voltage from D5 is below the positive threshold of IC1c, its output will be high and IC1a will be able to oscillate. Hence, the oscillator will pulse on and off, to maintain the 500V set by VR1.

Each time there is a discharge in the GM tube, the resultant current triggers the BT149 SCR which discharges the associated 100nF capacitor and thereby acts as a pulse stretcher to drive the three remaining inverters in IC1. These in turn drive a high-brightness red LED (LED1), a piezo transducer and an analog metering circuit which is based on an old VU meter movement with a scale graduated in counts/minute. The current drain of the circuit is 10mA and a small 9V battery should run the counter for many hours. Warning: do not touch the window of the GM tube. These are very fragile and made of very thin mica, to allow the low-energy alpha particles to pass through. With the LND 712, 200 counts per minute is roughly equivalent to 0.3 micro-seiverts.

Comments

Popular posts from this blog

Digital Fan Regulator Circuit Diagram

This is the project of Digital Fan Regulator Circuit diagram. The circuit presented here can be used to control the speed of  fans using induction motor. The speed control is nonlinear, i.e. in steps. The current step number is displayed on a 7-segment display. Speed can be varied over a wide range because the circuit can alter the voltage applied to the fan motor from 130V to 230V RMS in a maximum of seven steps.  The triac used in the final stage is fired at different angles to get different voltage outputs by applying short-dura-tion current pulses at its gate. For this pur-pose a UJT relax-ation oscillator is used that outputs sawtooth waveform. This waveform is coupled to the gate of the triac through an optocoupler (MOC3011) that has a triac driver output stage.  Pedestal voltage control is used for varying the firing angle of the triac. The power supply for the relaxation oscillator is derived from the rectified mains via 10-kilo-ohm, 10W series dropping/limit-ing...

Home automation with Telegram BOT

The project I’m going to describe today it’s a sort of proof of concept that will demonstrate the possibility to remote control sensors and actuators (for example a couple of relays) via Telegram. Telegram is an instant messaging application, similar to the famous Whatsapp. Last June, the Telegram developers announced that a new set of APIs were available to develop bots. [ ]

24 Hour Timer

Description: These two circuits are multi-range timers offering periods of up to 24 hours and beyond. Both are essentially the same. The main difference is that when the time runs out, Version 1 energizes the relay and Version 2 de-energizes it. The first uses less power while the timer is running; and the second uses less power after the timer stops. Pick the one that best suits your application. Notes: The Cmos 4060 is a 14 bit binary counter with a built in oscillator. The oscillator consists of the two inverters connected to Pins 9, 10 & 11; and its frequency is set by R3, R4 & C3.The green Led flashes while the oscillator is running: and the IC counts the number of oscillations. Although it's a 14 bit counter, not all of the bits are accessible. Those that can be reached are shown on the drawing. By adjusting the frequency of the oscillator you can set the length of time it takes for any given output to go high. This output then switches the transistor; which in turn o...